Cowboy Aggregates – Uvalde · Phase 1 South LoopFES 46401 · UPRR Del Rio Sub MP 313.47–315.32
Connecting

Phase 1 progress

Track status by track feet

UPRR hand-off checklist

UPRR-owned welds without an accepted test

    Open punch items

      Progress since calls began

      Recent activity

      Click · Shift-click range · Ctrl-click add
      N

      Station view

      Each track laid out straight by station. Colors are current status; the dark band is UPRR ownership, the hatched band the 150 ft skeleton runout. Click a segment to inspect it.

      Scope of work matrix

      UPRR-installed items from Exhibit A sheet 3 of 13 (10/25/2026). Industry supplies; UPRR forces install unless noted.

      #ItemDescriptionQtyU/MTrackStation(s)StatusNote

      Weld register

      Every thermite and flash-butt weld. UPRR-owned welds (Trk A 0+00–3+90.50, Trk B 85+36.98–89+28.36, Del Rio Sub) need an accepted UT before the UPRR portion is reported complete.

      No.TrackStationTypeOwnerWeldedNDT reportResultRemarks

      NDT reports

      ReportFirmDateMethod / codeScopeResult

      Punch list

      Items dropped on the plan or added here. UPRR asked that punch items be addressed before the final walkthrough.

      #ItemTrackStationRaised byAssignedDueStatus

      Weekly coordination call

      Generated from the record. Close out the call to timestamp this week's position; the next sheet reports changes from it.

      Press "Build sheet".

      Call history

      DateTrk A surfacedTrk B surfacedLoop surfacedUPRR welds acceptedPlan stated

      Activity

      Every change to the record, newest first.